PizeNews

Pize adalah asisten pemrograman AI untuk komputasi ilmiah dan analisis statistik.

Akun

Sistem spektroskopi

HARPIA-TA

Sistem spektroskopi absorpsi transien

A compact transient-absorption spectrometer for UV to MIR pump–probe work, with modules for fluorescence, multi-pulse, and flash-photolysis measurements.

Fitur teknis

  • UV to MIR measurement range
  • Works at high repetition rates
  • Modules for TA, fluorescence, and FSRS
  • 8 ns delay with 8.3 fs steps (UV-VIS)
  • Pairs with Yb or Ti:Sapphire pumps

Spesifikasi teknis

HARPIA-TA – Transient absorption & pump-probe

ConfigurationUV-VISUV-VIS-NIRMIR
Rentang spektral probe350 – 1100 nm 1)350 – 1600 nm 1)2000 – 13 000 nm 2)
Rentang pompa240 – 2200 nm 2)240 – 2200 nm 2)450 – 2200 nm 3)
Rentang tunda (resolusi)8 ns (8.3 fs)8 ns (8.3 fs)4 ns (4.2 fs)
Temporal resolution≤ laser pulse duration≤ laser pulse duration≤ laser pulse duration
Laju pengulangan laser1 – 100 kHz1 – 100 kHz1 – 100 kHz
Maximum data acquisition rate3850 Hz3850 Hz100 kHz
ModeRefleksi dan transmisiRefleksi dan transmisiRefleksi dan transmisi
  1. Pump–probe measurements using Yb-based laser systems may exhibit blind spots at 515 nm and 1030 nm, corresponding to the second harmonic and the fundamental wavelength of the laser, where strong pump scattering can interfere with accurate detection.
  2. The range is determined by the OPA’s output spectrum.
  3. The wavelength range is configurable to 240 – 700 nm.

HARPIA-TA-FP – Flash photolysis – nanosecond transient absorption

ModuleHARPIA-TA-FPHARPIA-TA-FPHARPIA-TA-FP-UVHARPIA-TA-FP-UV
HARPIA-TA configurationUV-VISUV-VIS-NIRUV-VISUV-VIS-NIR
Probe spectral range 1)450 – 1100 nm450 – 1600 nm350 – 1100 nm350 – 1600 nm
Rentang pompa240 – 2200 nm 2)240 – 2200 nm 2)240 – 2200 nm 2)240 – 2200 nm 2)
Delay rangeup to 485 μsup to 485 μsup to 485 μsup to 485 μs
Temporal resolution2 ns2 ns1 ns1 ns
Probe laser repetition rate1850 Hz1850 Hz1850 Hz1850 Hz
Maximum data acquisition rate3850 Hz3850 Hz3850 Hz3850 Hz
ModeRefleksi dan transmisiRefleksi dan transmisiRefleksi dan transmisiRefleksi dan transmisi
  1. Pump–probe measurements using nanosecond laser systems may exhibit blind spots at 1064 nm, corresponding to the fundamental wavelength of the laser.
  2. The range is determined by the OPA’s output spectrum.

HARPIA-TF – Kerr gate, fluorescence upconversion & TCSPC

Measurement techniqueKerr gateFluorescence upconversionTCSPC
Spectral range380 – 1000 nm330 – 820 nm 1) 2)220 – 820 nm 3)
Rentang pompa240 – 2200 nm 4)240 – 2200 nm 4)240 – 2200 nm 4)
Temporal resolution≤ 1 ps≤ 1.4 x laser pulse duration< 180 ps or < 50 ps
Rentang tunda (resolusi)8 ns (8.3 fs)8 ns (8.3 fs)5 μs 5)
Compatible withTCSPCTCSPCKerr gate or fluorescence upconversion
DetectorCCDPMTPMT
ModeTransmissionTransmissionRefleksi dan transmisi
  1. The fluorescence detection range is extendable up to 1600 nm.
  2. Fluorescence detection may exhibit blind spots at 343 nm, 515 nm, and 1030 nm due to harmonic overlap.
  3. The spectral range is extendable with an additional NIR detector (measurement range 1000 – 1700 nm).
  4. The range is determined by the OPA’s output spectrum.
  5. Using FIFO-based acquisition, the temporal window can be extended up to ~1 s for monitoring longer-timescale processes.

HARPIA-TB – FSRS & multi-pulse time-resolved transient absorption

Measurement techniquePump for multi-pulse experimentsFSRS 1)
Rentang spektral probedepends on the HARPIA-TA configuration350 – 1100 nm 2)
Raman spectral rangen/a700 – 2000 cm⁻¹
Acceptable wavelength range450 – 2200 nm 3)450 – 2200 nm 3)
Rentang tunda (resolusi)4 ns (4.2 fs)4 ns (4.2 fs)
ModeTransmissionTransmission
  1. The results were obtained using a specific system configuration: a PHAROS femtosecond laser, an ORPHEUS-HE OPA, and an SHBC combined with an ORPHEUS-PS OPA. Measurements were performed at a 10 kHz repetition rate with a 540 nm actinic pump and a 450 nm Raman pump. β-carotene was used as the sample.
  2. The system may exhibit blind spots at 515 nm and 1030 nm, corresponding to the second harmonic and fundamental wavelength of the laser, where strong pump scattering can interfere with accurate detection.
  3. The wavelength range is configurable to 240 – 700 nm.

Dimensi

ModelPhysical dimensions (L × W × H) 1)
HARPIA-TA730 × 420 × 183 mm
HARPIA-TA sample chamber area (L × W)205 × 216 mm
HARPIA-TF571 × 275 × 183 mm
HARPIA-TB670 × 252 × 183 mm
  1. Without an external spectrograph.